Vanquish Horizon |
Vanquish Flex |
Vanquish Core |
|
Unrivaled performance and throughput for applications requiring high-end UHPLC | Binary or quaternary solvent blending for fast and reliable UHPLC or flexible method development | Remove any disruptions from your routine HPLC analyses | |||
Performance |
System pressure | Up to 1500 bar |
Up to 1000 bar |
Up to 700 bar |
|
Retention time precision | |||||
Flow range | 5 mL/min |
8 mL/min |
10 mL/min |
||
Biocompatibility | Yes | Yes | N/A | ||
Design | Modular | ||||
System components |
Pump | Vanquish Binary Pump H The pump with the highest backpressure at 1500 bar, and ideal for any gradient performance from shallow to ballistic |
Vanquish Binary Pump F UHPLC performance for demanding routine applications up to 1000 bar Vanquish Quaternary Pump F UHPLC performance with more solvent flexibility up to 1000 bar |
Vanquish Binary Pump C Simplicity and throughput for routine HPLC applications up to 700 bar Vanquish Quaternary Pump C Flexibility and dependability for routine HPLC applications up to 700 bar Vanquish Isocratic Pump C Simplicity for basic HPLC applications up to 700 bar |
|
Autosampler | Vanquish Split Sampler HT Excellent precision, accuracy, and short cycle times with innovative air-stream cooling and barcode reading for inventory management for all workflows up to 1500 bar |
Vanquish Split Sampler FT Enjoy the same benefits as the Vanquish Split Sampler HT for applications up to 1000 bar |
Vanquish Dual Split Sampler C/CT Delivering extreme dependability and reliability for routine HPLC applications up to 700 bar. Optional thermostatting for samples. |
||
Extended sample capacity | Vanquish Charger An intelligent, robotic rack and plate feeder that automatically loads samples in the autosampler and extends the sample capacity of all Vanquish samplers to up to 8832 samples (23 wellplates or 12 vial racks) with innovative air-stream cooling and barcode reading for inventory management |
||||
Column compartment | Vanquish Column Compartment H Provides two column thermostatting modes (still and forced air), active and passive solvent pre-heating, and post-column cooling for optimized control of your separations and advanced method transfer. Temperature range: 5–120 °C |
Vanquish Column Compartment C High performance and flexibility in thermostatting mode to simplify method transfer from any HPLC system. Temperature range: 5–85 °C |
|||
Virtually zero dead volume system connections | Viper UHPLC Fittings Kits Order all the UHPLC fittings and capillaries you need for your system or application in a single kit |
= Not applicable | = Poor | = Good | = Better | = Best |